Order Code |
Product Name |
|
H-06-05-M01 |
60L H2O2 Low-Temp Plasma Sterilizer |
Application
Hospital Lab, Endoscopy Center, Sterilization Supply Room, Operating Room
Feature & Technical specification
1. CE conformity. Product form: manual door cabinet type
2. Heating method: electric heating
3. Volume: 60L
4. Power supply: AC220V, 50Hz
5. Power: 2.6kVA
6. Sterilization room size (L×W×H): 61×35×32 (cm)
7. Outer box size (L×W×H): 75×63×145 (cm)
8. Sterilization chamber material aluminum: 5052
9. Outer box material: ABS board
10. Sterilization room temperature: 50℃±5℃
11. Working pressure: 50Pa~106kPa
12. The highest anti-stress value
13. The ambient humidity is not more than 75%
14. Select gas hydrogen peroxide (H2O2)
15. Hydrogen peroxide concentration: 58%~60%
16. Sterilization time is about 40min in fast mode and about 60min in enhanced mode
17. Air replacement and automatic ventilation, the number of ventilation and interval time can be freely set. The automatic control system starts to end with one key, and the whole process is automatically completed with printing records.
18. Display status display temperature, humidity, pressure, sterilization time, residual gas treatment time, times
19. The printer records and prints the sterilization information of the whole process for verification and verification
20. Temperature sensor The built-in temperature sensor automatically monitors the temperature in the cavity and the internal circulation system to ensure that the temperature in the cavity is maintained at 50°C
Within the accuracy range of 21.±5℃
22. The filter of the residual gas treatment device can have a filtration rate of not less than 99.5% for the particle diameter ≥ 0.3 μm
23. The leak rate of the sterilization room is measured under the conditions of no load, constant temperature of the sterilization room, test pressure of 50Pa, and measurement time of 1h, and the average leakage rate within the measurement time is ≤0.1kPa/min
24. The sealing door adopts manual opening and closing door, which is easy to operate, fast vacuum rate and long service life
25. A variety of protection functions are provided with over-voltage and over-temperature protection functions, which are safe and reliable
26. The alarm system has high temperature alarm system and ultra-low pressure alarm system