100L H2O2 Low-Temp Plasma Sterilizer

Retail price
0.0
Yuan
Market price
0.0
Yuan
Number of views:
1000
Product serial number
H-04-06-M05
Quantity
-
+
Stock:
0
1
Product description
Parameters

Order Code

Product Name

H-06-05-M02

100L H2O2 Low-Temp Plasma Sterilizer

Application

Hospital Lab, Endoscopy Center, Sterilization Supply Room, Operating Room

Feature & Technical specification

1. CE conformity.  Product form: automatic door cabinet type

2. Heating method: electric heating

3. Volume: 100L

4. Power supply: AC220V, 50Hz

5. Power: 3.4kVA

6. Sterilization room size (L×W×H): 70×43×36 (cm)

7. Outer box size (L×W×H): 112×80×175 (cm)

8. Sterilization chamber material aluminum: 5052

9. Outer box material: ABS board

10. Sterilization room temperature: 50℃±5℃

11. Working pressure: 50Pa~106kPa

12. The highest anti-stress value

13. The ambient humidity is not more than 75%

14. Select gas hydrogen peroxide (H2O2)

15. Hydrogen peroxide concentration: 58%~60%

16. Sterilization time is about 40min in fast mode and about 60min in enhanced mode

17. Air replacement automatic ventilation, the number of ventilation and interval time can be set freely

18. The automatic control system starts to end with one key, and the whole process is automatically completed. The status is displayed with printing records. Display temperature, humidity, pressure, sterilization time, residual gas treatment time, and times.

19. The printer records and prints the sterilization information of the whole process for verification and verification

20. Temperature sensor The built-in temperature sensor automatically monitors the temperature in the cavity and the internal circulation system to ensure that the temperature in the cavity is kept within the accuracy range of 50°C ±5°C

21. The filter of the residual gas treatment device can have a filtration rate of not less than 99.5% for the particle diameter ≥ 0.3μm

22. The leak rate of the sterilization room is measured under the conditions of no load, constant temperature of the sterilization room, test pressure of 50Pa, and measurement time of 1h. The average leak rate within the measurement time is ≤0.1kPa/min

23. The sealing door adopts electric push rod to automatically open and close the door, which is easy to operate, fast vacuum rate and long service life

24. A variety of protection functions are provided with over-voltage and over-temperature protection functions, which are safe and reliable

25. The alarm system has high temperature alarm system and ultra-low pressure alarm system