Category
Related Products
|
Order Code |
Product Name |
|
A-05-02-M01 |
Veterinary 20KW Tabletop DR | Animal Digital Radiography System | FKNMED |

The Veterinary 20KW Tabletop DR is a professional digital radiography system designed for veterinary hospitals, animal laboratories and third-party diagnostic institutions. Integrating adjustable imaging parameters, flexible floating bed technology and dual-focus imaging design, it provides stable radiographic imaging performance for companion animals and livestock examination workflows. With 220V and 380V power supply options and customizable configurations, it supports diverse veterinary clinical and laboratory environments.
This Veterinary DR system is designed for Veterinary Radiology Rooms, Pet Radiology Rooms, Animal Radiology Rooms and veterinary examination environments. It is suitable for professional pet hospitals, veterinary clinics, livestock breeding facilities and veterinary testing institutions for animal full-body radiographic examination, skeletal screening, thoracic examination and abdominal imaging applications.
The system can integrate with veterinary examination, veterinary laboratory and animal healthcare workflows, supporting standardized procurement requirements from veterinary equipment distributors, importers and professional animal healthcare organizations.
The system supports 40–125KV adjustable voltage with 1KV step adjustment, multi-range mA and mAs settings, and precise exposure control from 0.003 to 6.3 seconds. The dual-focus design of 0.6×0.6mm and 1.2×1.2mm supports imaging requirements for different animal sizes and examination scenarios. Laser alignment mode helps improve positioning consistency during radiographic operations.
With 20KW aggregate capacity, 140KHU heat capacity and 2800rpm rotating speed, the Veterinary 20KW Tabletop DR supports continuous imaging operations in veterinary hospitals and animal diagnostic facilities. Dual power supply compatibility and optional generator frequency configurations allow adaptation to different regional power environments.
The 15.6-inch touch screen and preset clinical conditions simplify parameter adjustment and operation procedures. The four-way floating bed with electromagnetic locking provides flexible animal positioning, helping improve imaging preparation efficiency and daily examination workflow.
The equipment is designed for integration into veterinary radiology and animal diagnostic workflows. Its imaging operation system, parameter adjustment functions and output specifications support standardized veterinary clinical and laboratory applications.
FKNMED Veterinary 20KW Tabletop DR provides a professional imaging solution with stable configuration options, durable structural design and flexible customization capabilities. It is suitable for veterinary institutions, animal laboratories and international B2B procurement projects requiring reliable digital radiography equipment.
| Item | Parameter |
|---|---|
| Aggregate Capacity | 20KW |
| Service Voltage | 220V / 380V |
| Power Requirement | Single phase 3 wire 220V/50HZ; Three-phase 4 wire 380V/50HZ (line diameter >4 mm², internal resistance <0.5Ω) |
| mA Range | 10-320mA / 32-320mA |
| mAs Range | 0.1-320mAs / 1-320mAs, step R'10 |
| KV Range | 40-125KV, 1KV step |
| Exposure Time | 0.003~6.3s (34 steps), 1ms fine-tune increment/decrement |
| Focal Spot Size | 0.6×0.6mm / 1.2×1.2mm dual focus |
| Speed & Heat Capacity | 2800rpm / 140KHU |
| Generator Frequency | 30Khz / 400Khz (Optional) |
| Bed Surface Size | 70×140cm / 70×120cm (Optional), movable 40cm / 20cm |
| Core Configuration | 15.6-inch touch screen, four-way floating bed with electromagnetic locking, laser alignment mode, multiple tube options (Toshiba/domestic) |
Optional configurations include different generator frequency options, bed surface sizes and X-ray tube selections to meet different veterinary hospital and animal laboratory requirements.
FKNMED Veterinary 20KW Tabletop DR is developed for international veterinary equipment markets, supporting professional veterinary hospitals, animal laboratories and distributors with stable supply capability and flexible configuration options. With reliable imaging functions, efficient operation design and customization support, FKNMED helps global partners establish professional animal diagnostic imaging solutions.
Q1. How to select a 20KW tabletop DR system for veterinary hospitals?
Selecting a 20KW tabletop DR system requires evaluation of clinical applications, animal size range, imaging workload, facility space, and workflow requirements. Veterinary hospitals should consider whether the system supports routine examinations, orthopedic imaging, thoracic and abdominal studies, and high-frequency diagnostic operations. Procurement teams should review generator capability, detector configuration, table design, image processing workflow, maintenance requirements, and compatibility with existing veterinary information systems. A suitable tabletop DR solution should provide stable imaging performance and support efficient veterinary diagnostic workflows from animal examination to clinical evaluation.
Q2. Which animals can be examined using a 20KW veterinary tabletop DR system?
A 20KW tabletop DR system is designed for veterinary diagnostic imaging applications involving small and medium-sized animals, depending on clinical requirements and patient positioning capacity. It can support examinations commonly performed in veterinary hospitals, including companion animal radiography and other routine diagnostic imaging procedures. Veterinary professionals should evaluate animal size, anatomical region, examination frequency, and positioning requirements before selecting equipment. Proper configuration helps ensure the system matches the hospital’s patient population and daily imaging workflow.
Q3. How does a 20KW tabletop DR system improve veterinary diagnostic imaging efficiency?
A tabletop DR system improves veterinary imaging efficiency by providing a fixed examination platform, integrated workflow, and rapid digital image acquisition. Compared with mobile imaging setups, fixed tabletop systems can support standardized positioning procedures and consistent examination environments. Veterinary technicians can complete image acquisition, review, and communication more efficiently within the clinical workflow. This helps veterinary hospitals manage routine diagnostic imaging demand while improving coordination between radiography procedures and clinical decision-making.
Q4. What factors should veterinary clinics consider when selecting a detector and tabletop configuration?
Detector and tabletop selection should match the hospital’s animal population, examination requirements, and operational workflow. Veterinary clinics should evaluate detector size, positioning flexibility, table dimensions, patient handling requirements, and image quality expectations. The configuration should support common applications such as thoracic, abdominal, and orthopedic imaging while allowing technicians to perform examinations efficiently. Procurement managers should also consider equipment durability, cleaning procedures, and long-term maintenance requirements when selecting a tabletop DR system.
Q5. Can a 20KW tabletop DR system support orthopedic examinations in veterinary practice?
A 20KW tabletop DR system can support orthopedic imaging workflows where digital radiography is required for evaluation of bones, joints, and related anatomical structures. Veterinary teams should apply appropriate positioning techniques and standardized imaging protocols to obtain consistent diagnostic images. Orthopedic examinations often require accurate patient positioning and repeatable workflows, making a fixed tabletop system suitable for veterinary hospitals performing regular musculoskeletal assessments. Proper technician training is important for maintaining image quality and reducing unnecessary repeat examinations.
Q6. How can veterinary technicians improve image consistency with tabletop DR?
Image consistency depends on standardized operating procedures, correct patient positioning, appropriate exposure selection, and regular equipment management. Veterinary hospitals should establish imaging protocols based on animal type, examination area, and clinical purpose. Training technicians in patient preparation, positioning accessories, exposure workflow, and image evaluation helps improve operational consistency. Routine quality checks and maintenance procedures also support reliable performance for facilities with continuous veterinary radiography requirements.
Q7. Can tabletop DR systems integrate with veterinary PACS and medical record workflows?
Digital radiography systems can support modern veterinary imaging workflows by enabling digital image management, storage, review, and communication. Veterinary hospitals should evaluate system compatibility with their existing PACS, electronic veterinary medical records, and internal reporting procedures before purchase. Effective image management helps connect radiographic examination results with patient records and clinical evaluation processes. Procurement teams should consider software compatibility and workflow integration as important factors during equipment selection.
Q8. What maintenance is required for a veterinary 20KW tabletop DR system?
Regular maintenance is essential to maintain stable imaging performance and reduce operational interruptions. Veterinary facilities should follow recommended procedures for cleaning the tabletop surface, detector components, positioning accessories, and system interfaces. Routine inspection of the X-ray generator, tube assembly, cables, and other components helps identify potential issues early. Hospitals should establish maintenance schedules, operation records, and staff training procedures to support continuous diagnostic imaging capability.
Q9. What radiation safety factors should veterinary buyers evaluate before purchasing tabletop DR equipment?
Veterinary buyers should evaluate radiation safety requirements, local regulations, facility conditions, operator training, and protective procedures before installing tabletop DR equipment. Important considerations include appropriate room preparation, shielding requirements, safe operating practices, and staff awareness of radiation protection procedures. Procurement teams should ensure that the selected system can be integrated into the hospital’s existing safety management process. Proper training and standardized operation help maintain a safe imaging environment for veterinary staff and patients.
Q10. Which specifications should procurement managers compare before purchasing a 20KW tabletop DR system?
Procurement managers should compare specifications related to clinical application, imaging workflow, system configuration, and long-term operation. Key evaluation factors include generator capability, detector options, tabletop design, image processing functions, software compatibility, maintenance requirements, and supplier support capability. Buyers should also consider expected imaging volume, future expansion needs, and equipment reliability. A comprehensive evaluation helps veterinary hospitals, distributors, and importers select a tabletop DR system suitable for professional veterinary diagnostic applications.
{ "@context": "https://schema.org", "@graph": [ { "@type": "Organization", "@id": "https://www.fknmed.com/veterinary-equipment/#organization", "name": "Nanjing FKN Medical Tech Co., Ltd", "url": "https://www.fknmed.com/Veterinary-equipment/", "contactPoint": { "@type": "ContactPoint", "telephone": "+86 13770648803", "email": "liu-liming@fknmed.com", "contactType": "customer service" } }, { "@type": "Product", "@id": "https://www.fknmed.com/veterinary-tabletop-dr/veterinary-20kw-tabletop-dr.html#product", "name": "Veterinary 20KW Tabletop DR", "image": "https://www.fknmed.com/static/upload/image/20260815/1786777482172515.jpg", "description": "Veterinary 20KW Tabletop DR is a professional digital radiography system designed for veterinary hospitals, animal laboratories and diagnostic institutions. It provides adjustable imaging parameters, floating bed technology and dual-focus imaging functions for animal radiography workflows.", "brand": { "@type": "Brand", "name": "FKNMED" }, "manufacturer": { "@id": "https://www.fknmed.com/veterinary-equipment/#organization" }, "offers": { "@type": "Offer", "url": "https://www.fknmed.com/veterinary-tabletop-dr/veterinary-20kw-tabletop-dr.html", "availability": "https://schema.org/InStock" } } ] }Contact Information
E-mail:
Tel:
Address : Room 2512, Unit 1, Huaqiao Square, No.1, Daqiao North Road, Jiangbei New District, Nanjing, China
Veterinary Equipment
Medical Equipment