aoyang aoyang

Mining Lab Supplies

Category

Related Products

There is currently no content to display
Please add data record on website background.
< >

PTFE Filter Holder OD 47mm for Mining Laboratory Filtration and Trace Analysis

Retail price
0.0
Yuan
Market price
0.0
Yuan
Number of views:
1000
Product serial number
H-04-06-M05
Quantity
-
+
Stock:
0
1
Product description
Parameters

Order Code

Product Name

L-10-02-M07

PTFE Filter Holder OD 47mm for Mining Laboratory Filtration and Trace Analysis

PTFE Filter Holder OD 47mm for Mining Laboratory Filtration and Trace Analysis

PTFE Filter Holder for corrosive solution filtration analysis

Brief Introduction

The PTFE Filter Holder with OD 47mm membrane compatibility is a high-purity filtration assembly designed for vacuum and pressure-driven filtration of aggressive chemical solutions in analytical laboratories. Manufactured from 100% high-purity PTFE material, it provides a clean filtration pathway with excellent chemical resistance for mineral sample preparation and trace analysis workflows.

Equipped with customizable sealing options including FKM, FFKM and PFA/FEP encapsulated O-rings, this filter holder supports reliable leak-proof operation under demanding chemical conditions. The precision membrane support structure maintains stable filtration performance and helps improve consistency during repetitive laboratory pretreatment procedures.

Application Scope

This PTFE Filter Holder is widely used in mining laboratories for mineral sample preparation, metallurgical testing, hydrometallurgical solution purification and trace element analysis. It is suitable for filtration of concentrated mineral acids, hydrofluoric acid and aggressive organic solvents used in ore digestion and analytical pretreatment.

In hydrometallurgical evaluation workflows, the filter holder supports purification and clarification of corrosive process solutions before elemental composition testing. It is also applicable for environmental monitoring, pharmaceutical solution filtration and semiconductor ultra-clean fluid processing where high-purity filtration components are required.

Features

High-Purity PTFE Filtration Path for Reliable Analysis

Constructed from 100% high-purity PTFE material, the filter holder provides a clean fluid pathway with resistance to metal ion and silica leaching. It helps reduce contamination risks during corrosive solution filtration and supports stable analytical results for mineral and metallurgical testing.

Professional Sealing Options for Different Chemical Conditions

The filter holder supports multiple O-ring sealing configurations for different laboratory requirements. FKM seals are suitable for general laboratory and standard mineral acid filtration, FFKM seals provide resistance for aggressive chemical environments, and PFA/FEP encapsulated seals support ultra-clean filtration applications requiring enhanced chemical inertness.

Precision Membrane Support Improves Filtration Efficiency

The perforated PTFE membrane support plate provides uniform pressure distribution across OD 47mm filter membranes. This structure helps prevent membrane damage, fluid bypass and uneven filtration, improving workflow stability during repeated laboratory sample preparation operations.

Flexible Configuration for Mining Laboratory Integration

Supporting customized connector options including PFA hose barbs, NPT threads and flare fittings, the filter holder can integrate with existing PFA tubing, PTFE flasks and PFA vials. Multi-stage serial filtration configurations are also available for different mineral solution purification workflows.

Durable Chemical Resistance for Long-Term Operation

The PTFE structure provides excellent corrosion resistance and supports extended service life in demanding laboratory environments. Custom configurations reduce compatibility issues, while stable leak-proof performance helps minimize repeated filtration failures and maintenance requirements.

Specification

Product NamePTFE Filter Holder
Main Material100% High-purity PTFE
Applicable Membrane SizeOD 47mm
Core PerformanceZero metal and silica leaching, vacuum-tight leak-proof filtration
Chemical CompatibilityInert to concentrated HF, HNO3 and aggressive organic solvents
Standard Sealing OptionsFKM: For general laboratory and standard mineral acid filtration;
FFKM: For extreme temperature and aggressive solvent environments;
PFA/FEP Encapsulated: For ultra-clean trace analysis requirements
Support StructurePerforated PTFE membrane support plate with low flow resistance
Applicable ScenariosMining trace metal analysis, mineral acid filtration, environmental monitoring, pharmaceutical research and semiconductor ultra-clean filtration

Other Specification for Option

Fully customizable configurations are available, including membrane support structures, connector types such as PFA hose barbs, NPT threads and flare fittings, as well as multi-stage serial filtration assemblies to match specific laboratory workflow requirements.

Why Choose FKN PANDA

FKN PANDA supplies high-purity PTFE Filter Holders designed for global mining laboratories, hydrometallurgical testing facilities and analytical research environments. Manufactured with pure PTFE materials and professional sealing systems, these filtration assemblies support reliable performance in corrosive mineral solution processing.

With precision membrane support, flexible connection options and stable leak-proof operation, FKN PANDA filter holders help improve filtration consistency, optimize laboratory pretreatment workflows and reduce long-term operational costs. They provide dependable filtration solutions for mining technical teams, laboratory operators and professional distribution partners.

PTFE Filter Holder for 47mm Membrane – FAQ

Q1. How to select PTFE filter holders for 47mm membranes in mineral acid digestion residue filtration?

PTFE filter holders for 47mm membranes should be selected according to the sample characteristics, filtration method, and chemical environment of the mining laboratory workflow. Key considerations include compatibility with acidic digestion residues, membrane size requirements, vacuum filtration setup, and expected solids loading. In mineral analysis and hydrometallurgical testing, the filter holder should support stable membrane positioning and reliable separation of solid residues before downstream analysis such as elemental determination or metallurgical evaluation.

Q2. What factors should be considered when choosing PTFE filter holders for hydrometallurgical leachate analysis?

When selecting PTFE filter holders for hydrometallurgical applications, laboratories should consider chemical compatibility, filtration consistency, connection compatibility, and ease of sample handling. Leachate samples may contain corrosive reagents, fine mineral particles, and dissolved metal components, requiring filtration equipment that maintains sample integrity. PTFE construction is commonly considered for applications requiring high chemical resistance, while the holder configuration should match the laboratory’s existing vacuum filtration workflow and analytical requirements.

Q3. How does PTFE filter holder chemical resistance affect mineral testing laboratory applications?

Chemical resistance is an important factor when using filter holders in mineral testing and metallurgical laboratories. PTFE materials are suitable for many aggressive chemical environments, helping reduce risks associated with contact between filtration components and acidic or reactive sample solutions. During workflows such as ore digestion residue filtration, hydrometallurgical leachate preparation, and trace element analysis, appropriate material selection supports sample purity and helps maintain consistent filtration performance.

Q4. What are the differences between PTFE and glass filter holders for mineral testing laboratory vacuum filtration?

PTFE and glass filter holders have different application considerations in mining laboratory filtration. PTFE holders are often selected for workflows involving aggressive chemical solutions because of their chemical resistance, while glass holders may be preferred where visual observation of filtration conditions is important. The choice depends on factors such as sample chemistry, operating conditions, membrane compatibility, and laboratory procedures. For acid digestion and hydrometallurgical applications, material compatibility is a key selection factor.

Q5. How to optimize vacuum pressure settings when using PTFE filter holders with high-resistance 47mm membranes?

Vacuum pressure should be adjusted according to membrane characteristics, sample viscosity, particle concentration, and filtration resistance. Excessive vacuum conditions may influence filtration behavior, while insufficient vacuum may reduce processing efficiency. In mining laboratories, operators typically optimize filtration conditions during method development by considering the ore sample type, residue properties, and required analytical accuracy. Proper vacuum control helps maintain stable solid-liquid separation during mineral testing workflows.

Q6. How to ensure testing repeatability across multiple PTFE filter holders in mineral processing evaluation workflows?

Testing repeatability depends on consistent filtration conditions, correct membrane installation, proper cleaning procedures, and standardized operating methods. Laboratories using multiple PTFE filter holders should maintain consistent assembly procedures, sample preparation methods, and vacuum operating parameters. In mineral processing evaluation, repeatable filtration performance supports reliable comparison of ore samples, leaching residues, and metallurgical test results throughout sample preparation and analytical workflows.

Q7. Which 47mm membrane compatibility requirements are important for PTFE filter holders in trace metal analysis?

For trace metal analysis, PTFE filter holders should be matched with suitable 47mm membrane specifications, including diameter compatibility, chemical resistance, and retention characteristics. The selected membrane should align with the analytical method and sample type, especially when preparing digestion residues or leach solutions before instrumental analysis. Proper membrane and holder compatibility helps reduce sample loss, contamination risks, and variability during mineral characterization procedures.

Q8. How to integrate 47mm PTFE filter holders into existing mineral testing laboratory workflows?

47mm PTFE filter holders can be integrated into laboratory workflows by matching them with existing vacuum filtration systems, compatible membranes, and established sample preparation procedures. They are commonly applied in stages between sample digestion or leaching and final analytical testing. During laboratory expansion or equipment replacement, compatibility with current vacuum pumps, filtration accessories, and analytical preparation methods should be evaluated to maintain operational consistency.

Q9. What maintenance practices help reduce contamination risks when reusing PTFE filter holders for multi-element ore analysis?

Proper maintenance procedures are important when PTFE filter holders are reused in multi-element analysis workflows. Laboratories should follow appropriate cleaning practices based on the sample chemistry, inspect sealing components regularly, and prevent residue accumulation in filtration areas. Effective maintenance helps reduce cross-contamination risks between different ore samples and supports reliable results during mineral testing, hydrometallurgical evaluation, and trace element analysis.

Q10. What are the critical specifications for PTFE filter holders used in aggressive acid leaching and metallurgical testing?

Important specifications for PTFE filter holders in aggressive acid leaching applications include material compatibility, membrane size support, connection design, sealing reliability, and suitability for vacuum filtration conditions. In metallurgical laboratories, the holder should support stable filtration of residues generated from processes such as acid digestion, leaching evaluation, and mineral separation studies. Selecting the appropriate configuration helps laboratories maintain efficient sample preparation and reliable analytical workflows.

{ "@context": "https://schema.org", "@graph": [ { "@type": "Organization", "@id": "https://www.fknmed.com/mining-lab-supplies/#organization", "name": "FKN GROUP LIMITED", "contactPoint": { "@type": "ContactPoint", "telephone": "+86 13770648803", "email": "liu-liming@fknmed.com", "contactType": "customer service" } }, { "@type": "Product", "@id": "https://www.fknmed.com/vacuum-filtration-systems/ptfe-filter-holder.html#product", "name": "PTFE Filter Holder OD 47mm for Mining Laboratory Filtration and Trace Analysis", "description": "High-purity PTFE Filter Holder designed for corrosive solution filtration, mineral sample preparation, hydrometallurgical testing and trace analysis workflows.", "image": "https://www.fknmed.com/static/upload/image/20260727/1785122861196371.jpg", "brand": { "@type": "Brand", "name": "FKN PANDA" }, "manufacturer": { "@id": "https://www.fknmed.com/mining-lab-supplies/#organization" }, "offers": { "@type": "Offer", "url": "https://www.fknmed.com/vacuum-filtration-systems/ptfe-filter-holder.html", "availability": "https://schema.org/InStock" } } ] }
Inquiry now
Username used for comment:
客户留言
Description:

Contact Information

E-mail:

 

Address : Room 2512, Unit 1, Huaqiao Square, No.1, Daqiao North Road, Jiangbei New District, Nanjing, China

 

You can share with everyone

Nanjing Fukon Tech Co., Ltd.
© Copyright 2024 FKN Group Limited