Veterinary Phacoemulsification System

l Clinical Applications:

This Ultrasonic Phaco Emulsifier is used for veterinary surgery of cataract extraction.

l Components:

It consists of the Main Unit, U/S (Phaco Emulsification) Handpiece, Bipolar Cautery Forceps, Vitrector, I/A (Irrigation/Aspiration) Handpiece, Footswitch and accessories (including U/S Tip, U/S and/or I/A Sleeves, U/S and/or I/A Test Chamber and Vitrectomy Irrigation Sleeve).

l Specifications:

Phaco Emulsification

Phaco Emulsification Frequency: 40KHz±20%; U/S Handpiece Top End Vibration Accuracy: Max. 120μm±20%; Stimulating Power Range: 0~100%, soft keyboard input or adjustable stepping, Step: 1%; Pulse Frequency:1Hz~99Hz, soft keyboard input or adjustable stepping, Step:1Hz; Effective emulsification time:1%~99% (≥5ms); Soft Keyboard Input or Adjustable Stepping: Step:1%; display accuracy: ≤±10%; Burst Time: 5ms~100ms, soft keyboard input or adjustable stepping; Step:1ms; display accuracy:≤±10%; Max. Vacuum:66.7kPa (500mmHg); display accuracy: ≤±15%; Max. Flow Rate: 40 ml/min; display accuracy: ≤±20%

High-Frequency Cautery

Rating Frequency: 1MHz±20%; Max. Output Power: 10W±20% (200Ω Load); Output Adjustable Range: 0~100%, soft keyboard input or adjustable stepping, Step: 1%; display accuracy: ≤±20%

Vitrectomy

Cutting Frequency: single mode or (20~600) times/min, soft keyboard input or adjustable stepping, step of 5 times/min, display accuracy: ≤ ±15%; Max. Vacuum: 66.7kPa (500mmHg), display accuracy: ≤ ±15%; Maximum Flux Rate: 40 ml/min, display accuracy: ≤ ±20%

Irrigation/Aspiration

Vacuum Range: 1mmHg~500mmHg; Flow Rate: 1 ml /min~40 ml /min; Max. Vacuum: 66.7kPa (500mmHg), display accuracy: ≤ ±15%; Max. Flow Rate: 40 ml/min, display accuracy: ≤ ±20%; Reflux Rate: 20 ml/min±20%

l Certificates:

CFDA、ISO13485

l Accessories: 

Consumables


Inquiry now
Username used for comment:
客户留言
Description:

Contact Information

E-mail:

 

Address : Room 2512, Unit 1, Huaqiao Square, No.1, Daqiao North Road, Jiangbei New District, Nanjing, China

 

You can share with everyone

Nanjing Fukon Tech Co., Ltd.
© Copyright 2024 FKN Group Limited