Category
Related Products
|
Order Code |
Product Name |
|
L-01-12-M07 |
Jacketed Stainless Steel Laboratory Turbine Extraction Tower for Hydrometallurgy |

The Jacketed Stainless Steel Laboratory Turbine Extraction Tower is a high-efficiency differential continuous contact extraction unit designed for precision laboratory and pilot-scale liquid-liquid separation tests. Using a segmented turbine stirring structure, the tower body is divided into multiple independent theoretical stages through porous static sieve rings.
Each compartment is equipped with a shaft-driven turbine mixer that generates turbulent shear flow to disperse liquid droplets and enhance interphase mass transfer. Compared with traditional rotating disc towers, the turbine mixing structure provides stronger mixing performance and more uniform droplet dispersion.
Based on droplet group hydrodynamic principles, the equipment achieves stable continuous counter-current contact between light and heavy phases. The integrated system includes upper and lower oil-water separators, rotating turbine system, feeding structure and electric control system. The jacketed tower design provides temperature-controlled extraction conditions for hydrometallurgical separation, chemical purification and process verification.
The Jacketed Stainless Steel Laboratory Turbine Extraction Tower supports mining and metallurgical laboratory workflows including mineral sample preparation, metallurgical testing, mineral analysis and hydrometallurgical process evaluation.
The equipment performs continuous purification and impurity removal of metallurgical leachate and crude process solutions. Stable multi-stage counter-current mixing and separation generate homogeneous liquid samples with consistent composition for subsequent mineral component detection and grade analysis.
This turbine extraction tower supports valuable metal separation and impurity removal studies in nickel-cobalt hydrometallurgy. It is applied for zinc removal from nickel and cobalt solutions and uranium recovery from leachate and crude phosphoric liquid, helping technicians evaluate extraction performance and optimize continuous process conditions.
The equipment simulates industrial tower-type continuous extraction processes and provides laboratory data for process amplification studies. Its reduced scale-up effect supports hydrodynamic and mass transfer evaluation from laboratory research toward industrial application. It can also be applied in petrochemical refining, fine chemical separation, fermentation processing and environmental liquid treatment experiments.
High-performance turbine mixing components improve liquid shear dispersion, increase single theoretical stage mass transfer efficiency and suppress axial backmixing for stable extraction operation.
The porous plate-type static ring structure optimizes two-phase contact conditions, maintains suitable dispersed phase retention and improves separation stability during continuous extraction.
Independent compartment circulation design minimizes differences between laboratory testing and larger-scale turbine extraction systems, supporting reliable process parameter evaluation.
Optimized turbine blade hydrodynamics generate consistent droplet size distribution and improve mixing performance for suitable liquid-liquid extraction systems.
The integrated jacketed structure enables controlled-temperature extraction conditions and supports experimental systems requiring stable thermal environments.
Tower dimensions and material configurations can be customized according to feed liquid properties, corrosiveness and process requirements for different laboratory and pilot applications.
| Parameter Item | Technical Data |
|---|---|
| Main Body Material | 304 Stainless Steel, 316L Stainless Steel, 2205 Duplex Steel |
| Structural Composition | Upper & Lower Oil-Water Separator, Jacketed Tower Body, Turbine Rotation System, Feeding System, Electric Control System |
| Working Principle | Continuous counter-current differential contact extraction |
| Core Structure | Multi-stage porous static ring compartment + turbine dynamic shear mixing |
| Customization | Customized tower inner diameter, height and configuration based on customer material systems |
All structural parameters and body materials can be customized according to experimental requirements. Users can select 304 stainless steel, 316L stainless steel or 2205 duplex steel based on liquid corrosiveness, temperature and physical properties of the feed material.
The tower height, inner diameter and stage quantity can be adjusted according to processing capacity and extraction process requirements, providing targeted equipment configurations for different experimental systems.
FKN PANDA Jacketed Stainless Steel Laboratory Turbine Extraction Tower provides reliable testing performance through optimized turbine shear mixing and segmented compartment design. Stable hydrodynamic operation and optional temperature-controlled jacket conditions support repeatable experimental environments for mineral analysis and hydrometallurgical process evaluation.
The stainless steel structure and mature shaft rotation transmission system provide operational reliability for continuous laboratory testing. Stable internal flow conditions help maintain consistent extraction performance during comparative experiments.
Continuous counter-current extraction workflow reduces manual intervention and improves laboratory productivity. The reduced scale-up effect helps shorten process verification cycles and supports transition from laboratory studies toward industrial production evaluation.
Designed for mining and metallurgical workflows, the equipment is suitable for hydrometallurgical metal separation, nickel-cobalt purification, leachate treatment and rare metal recovery experiments, providing reference data for industrial extraction process development.
Customizable dimensions, material options and multi-application capability help reduce unnecessary equipment investment while improving long-term maintenance efficiency for metallurgical laboratories and research facilities.
Q1. How to select a stainless steel laboratory extraction column with jacket for temperature-controlled SX testing?
Selecting a jacketed stainless steel laboratory extraction column requires consideration of process chemistry, temperature requirements, material compatibility, and experimental objectives. For solvent extraction studies, laboratories should evaluate whether the column design can provide stable temperature control, reliable phase contact, and repeatable operating conditions. Key factors include column configuration, jacket structure, connection design, instrumentation requirements, and compatibility with the organic and aqueous phases. Proper selection helps metallurgical engineers obtain representative data during hydrometallurgical testing and supports process evaluation from laboratory investigation to pilot-scale development.
Q2. Which hydrometallurgical applications require jacketed stainless steel extraction columns in laboratory settings?
Jacketed stainless steel extraction columns are suitable for hydrometallurgical research where temperature control influences extraction behavior, phase separation, or reagent performance. Typical applications may include solvent extraction studies for copper, nickel, cobalt, lithium, rare earth elements, and other mineral processing flowsheets. Controlled temperature operation allows researchers to investigate how thermal conditions affect mass transfer and process stability. In laboratory workflows, these columns support metallurgical evaluation by providing a controlled environment for studying extraction mechanisms and optimizing operating parameters before larger-scale testing.
Q3. What factors should be considered when specifying jacket design for laboratory SX columns?
Jacket design selection depends on the required temperature range, heat transfer requirements, process fluid characteristics, and laboratory operating conditions. Engineers should consider jacket configuration, thermal fluid circulation, connection type, insulation requirements, and integration with heating or cooling equipment. A properly designed jacket helps maintain more consistent operating temperatures during solvent extraction experiments. When planning new laboratory setups or equipment upgrades, the jacket system should be matched with the research objectives to ensure reliable temperature control and improve the repeatability of hydrometallurgical test results.
Q4. How does jacket temperature control affect extraction kinetics and phase behavior in laboratory SX columns?
Temperature can influence solvent extraction behavior by affecting chemical reaction rates, phase properties, viscosity, and separation characteristics. A jacketed extraction column allows researchers to maintain controlled thermal conditions while evaluating extraction performance. Stable temperature management helps laboratories study temperature-dependent process behavior and compare results under different operating conditions. For hydrometallurgical development, accurate thermal control provides useful information for understanding extraction kinetics and optimizing process parameters during mineral processing research, pilot evaluation, and scale-up studies.
Q5. How to integrate a jacketed stainless steel extraction column into a temperature-controlled laboratory SX circuit?
Integration requires coordination between the extraction column, temperature control system, solution circulation equipment, monitoring instruments, and sampling procedures. The jacketed column should be incorporated into the overall solvent extraction workflow so researchers can evaluate extraction, separation, and thermal effects under controlled conditions. Proper circuit design includes consideration of fluid flow paths, heat transfer requirements, and operating stability. This approach helps laboratories generate more representative metallurgical data and supports process decisions during hydrometallurgical development programs.
Q6. Which parameters most influence thermal gradient and mass transfer efficiency in jacketed lab SX columns?
Thermal gradient and mass transfer performance are influenced by factors such as jacket fluid circulation, temperature difference, column design, phase flow rates, fluid properties, and internal contacting conditions. During laboratory solvent extraction studies, engineers need to monitor these variables to understand their impact on extraction behavior. Maintaining consistent temperature distribution helps reduce uncertainty when comparing experimental results. A well-controlled jacket system supports reliable evaluation of process kinetics, phase interaction, and extraction performance in hydrometallurgical research applications.
Q7. How to calibrate temperature sensors in both column and jacket for accurate thermal control in SX experiments?
Temperature sensor calibration is important for maintaining reliable experimental conditions during temperature-sensitive solvent extraction tests. Calibration procedures should verify sensor readings, measurement consistency, and the relationship between the extraction column temperature and jacket temperature. Laboratories should follow appropriate equipment procedures and use suitable reference methods when checking temperature accuracy. Proper calibration supports repeatable test conditions, improves data quality, and helps researchers accurately evaluate the influence of temperature on extraction performance and phase behavior.
Q8. What maintenance requirements are critical for jacket seals, ports, and insulation in stainless steel lab extraction columns?
Maintenance of jacketed stainless steel extraction columns focuses on inspection of seals, ports, connections, insulation components, and areas exposed to process fluids or thermal cycling. Regular checks help identify potential leakage, mechanical wear, or reduced heat transfer performance. For continuous laboratory operation, maintaining the integrity of the jacket system is important for stable temperature control and reliable testing. A planned maintenance approach supports equipment longevity and helps laboratories maintain consistent performance during extended hydrometallurgical research programs.
Q9. How to reduce experimental error when evaluating temperature-dependent SX performance in jacketed columns?
Reducing experimental error requires consistent control of temperature, flow conditions, sampling procedures, and operating parameters. Laboratories should ensure that thermal conditions are stable before collecting analytical data and maintain proper documentation of test settings. Accurate monitoring of both process and jacket conditions helps researchers distinguish temperature effects from other variables. A controlled jacketed extraction column provides a reliable platform for studying temperature-dependent solvent extraction behavior and improving confidence in metallurgical evaluation results.
Q10. How to scale up results from a jacketed stainless steel laboratory column to pilot or industrial SX column design?
Scaling up from laboratory jacketed extraction columns requires evaluation of mass transfer behavior, temperature effects, flow distribution, residence time, and equipment configuration. Laboratory studies provide valuable information about how thermal conditions influence solvent extraction performance, but scale-up decisions must consider differences in size, throughput, and industrial operating requirements. By analyzing laboratory data together with pilot testing results, engineers can improve process understanding and support more reliable equipment selection and design decisions for larger hydrometallurgical applications.
{ "@context": "https://schema.org", "@graph": [ { "@type": "Organization", "@id": "https://www.fknmed.com/mining-lab-supplies/#organization", "name": "FKN GROUP LIMITED", "contactPoint": { "@type": "ContactPoint", "telephone": "+86 13770648803", "email": "liu-liming@fknmed.com", "areaServed": "International mining market" } }, { "@type": "Product", "@id": "https://www.fknmed.com/hydrometallurgy-testing-leaching-equipment/stainless-steel-laboratory-jacketed-extraction-column.html#product", "name": "Jacketed Stainless Steel Laboratory Turbine Extraction Tower for Hydrometallurgy", "description": "Jacketed stainless steel laboratory turbine extraction tower designed for temperature-controlled liquid-liquid separation, continuous counter-current extraction testing and hydrometallurgical process evaluation with customizable configurations.", "image": "https://www.fknmed.com/static/upload/image/20260726/1785045135894884.jpg", "brand": { "name": "FKN PANDA" }, "manufacturer": { "@id": "https://www.fknmed.com/mining-lab-supplies/#organization" }, "offers": { "@type": "Offer", "url": "https://www.fknmed.com/hydrometallurgy-testing-leaching-equipment/stainless-steel-laboratory-jacketed-extraction-column.html", "availability": "https://schema.org/InStock" } } ] }Contact Information
E-mail:
Tel:
Address : Room 2512, Unit 1, Huaqiao Square, No.1, Daqiao North Road, Jiangbei New District, Nanjing, China
Veterinary Equipment