Category
Related Products
|
Order Code |
Product Name |
|
L-01-07-M06 |
Programmable Laboratory Flocculation and Sedimentation Test System for Mining Slurry Testing |

The Laboratory Flocculation and Sedimentation Test System is a dedicated testing device designed for standardized flocculation, coagulation, and sedimentation experiments. Developed for professional laboratory water treatment and slurry conditioning analysis, the system provides programmable stirring sequences, gradient control, and real-time parameter monitoring to improve testing consistency.
With digital microcomputer control technology, the system supports multi-program storage, segmented stepless speed regulation, and independent or synchronous operation of multiple stirring shafts. It enables laboratories to simulate industrial flocculation processes under controlled conditions, providing reliable experimental data for flocculant evaluation, mineral processing research, and hydrometallurgical solid-liquid separation studies.
The system is applied for flocculation conditioning and sedimentation pretreatment of mining wastewater, tailings slurry, and process water. Controlled stirring and settling conditions help achieve consistent solid-liquid separation results for subsequent filtration and mineral component analysis.
This equipment supports metallurgical slurry conditioning experiments by evaluating the influence of flocculant dosage, stirring speed, and reaction time on separation performance. It provides standardized experimental data for beneficiation and wet metallurgy process parameter research.
The Laboratory Flocculation and Sedimentation Test System supports water quality testing and sedimentation performance evaluation of mine discharge water and circulating process water. Precise parameter control improves the accuracy and repeatability of laboratory sample analysis.
Suitable for flocculation and sedimentation tests involving leachate, washing solution, and residual slurry in hydrometallurgical experiments, the system assists laboratories in evaluating flocculation conditions and studying solid-liquid separation performance.
The system is widely used in universities, research institutions, water treatment facilities, chemical laboratories, petroleum laboratories, power industries, and pharmaceutical research for flocculant performance evaluation and process research.
Powered by a high-accuracy stepper motor with stable speed output, the system provides consistent stirring conditions for laboratory experiments. It supports G value gradient control from 10 to 1000 s⁻¹, helping standardize flocculation reactions and reduce manual operation variations.
The system stores up to 30 independent programs, with each program supporting 10-segment stepless speed adjustment and adjustable timing from 0 to 99 minutes and 59 seconds. This function allows laboratories to simulate multi-stage flocculation procedures and improve testing workflow efficiency.
Six stirring shafts support synchronous and asynchronous independent operation for parallel testing. The automatic vertical lifting structure helps protect formed alum flocs during experimental procedures, while adaptive G/GT value calculation supports different test conditions.
Equipped with a 7-inch bilingual color touch screen, the system displays speed, time, temperature, and gradient parameters in real time. Built-in LED lighting improves observation of floc formation and sedimentation processes. The automatic dosing function supports multi-stage reagent addition before each program segment.
The gearless non-mechanical transmission structure reduces risks associated with traditional belt and gear systems. The integrated body design and frosted stainless steel chassis provide corrosion resistance, wear resistance, and rust resistance for stable laboratory operation.
With complete supporting glass test cups and test tubes, the system is ready for laboratory use. Its multifunctional design integrates flocculation testing, sedimentation evaluation, and reagent performance studies, reducing equipment investment and maintenance requirements.
| Parameter Item | Specification |
|---|---|
| Power | 150W |
| Power Supply | AC 220V |
| Speed Range | 10~1200 rpm |
| Velocity Gradient G Value | 10~1000 s⁻¹ |
| Timing Range | 0~99 min 59 sec |
| Temperature Measuring Range | 0~50℃ |
| Program Storage Quantity | 30 sets (10 stepless speed segments per set) |
| Packing Dimensions | 90 × 30 × 50 cm |
FKN PANDA specializes in laboratory testing and pretreatment equipment for global mining, hydrometallurgical, environmental engineering, and industrial laboratories. Our equipment is designed to support standardized experimental procedures with stable operation, repeatable results, and practical workflow compatibility.
The Programmable Laboratory Flocculation and Sedimentation Test System integrates controlled stirring, visual monitoring, and auxiliary functions to overcome limitations of traditional manual flocculation experiments. It provides reliable support for mineral slurry conditioning, mine wastewater testing, reagent evaluation, and laboratory process research.
With durable construction, flexible program configuration, and complete supporting accessories, FKN PANDA delivers dependable laboratory solutions for mining companies, research institutions, and international distributors requiring consistent testing performance and long-term operational reliability.
Q1. How to select a flocculation and sedimentation test system for mineral processing laboratories?
Selecting a laboratory flocculation and sedimentation test system requires consideration of mineral characteristics, slurry properties, testing objectives, and process development requirements. Key factors include particle size distribution, solids concentration, mineral composition, and the type of thickening or tailings management study being conducted. A suitable system should support reliable evaluation of flocculant performance, settling behavior, and supernatant clarity. For mining laboratories involved in mineral processing, hydrometallurgy, or tailings research, proper equipment selection helps generate meaningful data for process optimization and thickener design decisions.
Q2. What factors influence flocculant selection for different ore slurries?
Flocculant selection depends on slurry characteristics such as mineral type, particle size, surface properties, solids concentration, and water chemistry. Different ores may respond differently to anionic, cationic, or non-ionic flocculants due to variations in particle interaction and surface charge. Laboratory flocculation tests help engineers compare reagent performance under controlled conditions before industrial application. By evaluating settling rate, sediment density, and liquid clarity, laboratories can identify suitable reagent options and support more efficient thickening and solid-liquid separation process development.
Q3. How to optimize flocculant dosage in laboratory settling tests?
Optimizing flocculant dosage requires systematic laboratory testing using different reagent concentrations while monitoring settling performance and overflow clarity. Excessive dosage may increase reagent consumption or affect slurry behavior, while insufficient dosage may result in poor particle aggregation and slow settling. Engineers typically evaluate dosage together with mixing conditions, slurry concentration, and pH to determine suitable operating ranges. A laboratory flocculation and sedimentation test system provides valuable data for establishing practical reagent addition strategies before scaling up to industrial thickening operations.
Q4. How does particle size distribution affect sedimentation behavior in mineral slurries?
Particle size distribution has a significant impact on sedimentation performance because fine particles generally settle more slowly and may require optimized flocculation conditions. Slurries containing a high proportion of ultrafine particles often present challenges in achieving clear overflow and compact underflow. Laboratory settling tests allow engineers to study the relationship between particle characteristics and floc formation behavior. Understanding these effects helps mineral processing teams evaluate thickening performance, optimize reagent selection, and improve solid-liquid separation strategies for different ore processing applications.
Q5. How can laboratories evaluate settling rate and clarity during flocculation experiments?
Laboratories evaluate flocculation performance by monitoring parameters such as settling velocity, interface movement, sediment volume, and supernatant clarity during controlled tests. These measurements provide information about particle aggregation behavior and separation efficiency. A laboratory flocculation and sedimentation test system allows engineers to compare different reagents, dosages, and operating conditions using consistent procedures. The collected data supports process evaluation for applications including mineral concentration, tailings treatment, and hydrometallurgical residue management where effective solid-liquid separation is required.
Q6. How can flocculation tests simulate industrial thickening conditions?
Laboratory flocculation tests can simulate industrial thickening conditions by adjusting key variables such as slurry concentration, reagent dosage, mixing intensity, and settling time. Although laboratory testing does not fully replace industrial trials, it provides important information for understanding slurry behavior and evaluating process options. Engineers use these results to compare flocculant performance, estimate thickener requirements, and identify potential challenges before scale-up. Proper test design helps bridge the gap between laboratory investigation and practical mineral processing applications.
Q7. How to ensure repeatability in flocculation and sedimentation test results?
Repeatability depends on standardized sample preparation, consistent reagent preparation, controlled mixing procedures, and accurate measurement methods. Laboratories should maintain stable testing conditions including slurry concentration, flocculant dosage, mixing energy, and observation time. Recording test parameters and results allows engineers to compare different samples and verify process trends. Regular cleaning and proper operation of the testing system also help minimize variation between experiments, supporting reliable data collection for mineral processing studies and thickening optimization.
Q8. Can a flocculation and sedimentation test system be used for gold, copper, and other mineral processing tailings?
A laboratory flocculation and sedimentation test system can be applied to evaluate tailings and process residues from various mineral processing operations, including gold, copper, and other ore treatment processes. The system helps researchers understand how different tailings respond to flocculants and how settling characteristics change under different conditions. Before application, laboratories should consider the specific mineral composition, particle size distribution, and water chemistry of each tailings sample. Test results can support decisions related to thickening, water recovery, and tailings management studies.
Q9. How does slurry pH influence flocculation efficiency?
Slurry pH can influence particle surface properties, reagent interaction, and floc formation behavior during sedimentation testing. Changes in pH may affect mineral surface charge, flocculant adsorption, and overall settling performance. Laboratory evaluation under different pH conditions helps engineers understand how chemical conditions impact solid-liquid separation. By combining pH testing with flocculant dosage and settling measurements, laboratories can develop more suitable operating parameters for mineral processing and hydrometallurgical applications where slurry chemistry plays an important role.
Q10. How should mining laboratories standardize flocculation testing procedures?
Standardizing flocculation testing procedures involves defining consistent methods for sample preparation, reagent preparation, mixing conditions, dosage evaluation, settling observation, and data recording. A structured testing protocol improves comparison between different samples, operators, and research programs. For mining laboratories involved in new process development, laboratory expansion, or equipment replacement, standardized procedures help maintain reliable quality control. Consistent flocculation testing provides valuable technical information for optimizing thickener operation, reagent consumption, and overall mineral processing performance.
{ "@context": "https://schema.org", "@graph": [ { "@type": "Organization", "@id": "https://www.fknmed.com/mining-lab-supplies/#organization", "name": "FKN GROUP LIMITED", "contactPoint": { "@type": "ContactPoint", "telephone": "+86 13770648803", "email": "liu-liming@fknmed.com", "areaServed": "International mining market" } }, { "@type": "Product", "@id": "https://www.fknmed.com/dewatering-solid-liquid-separation-equipment/laboratory-flocculation-sedimentation-test-system.html#product", "name": "Programmable Laboratory Flocculation and Sedimentation Test System for Mining Slurry Testing", "description": "Programmable Laboratory Flocculation and Sedimentation Test System designed for mining, metallurgical and hydrometallurgical laboratories. It provides precise stirring control, G value adjustment, programmable operation and repeatable flocculant evaluation.", "image": "https://www.fknmed.com/static/upload/image/20260729/1785306102374446.jpg", "brand": { "@type": "Brand", "name": "FKN PANDA" }, "manufacturer": { "@id": "https://www.fknmed.com/mining-lab-supplies/#organization" }, "offers": { "@type": "Offer", "url": "https://www.fknmed.com/dewatering-solid-liquid-separation-equipment/laboratory-flocculation-sedimentation-test-system.html", "availability": "https://schema.org/InStock" } } ] }Contact Information
E-mail:
Tel:
Address : Room 2512, Unit 1, Huaqiao Square, No.1, Daqiao North Road, Jiangbei New District, Nanjing, China
Veterinary Equipment