65.5KW High Frequency DR System |
Application
This device is a high frequency combined digital X-ray radiography medical diagnostic equipment, it is used in radiography department, orthopedics, wards, emergency room, operation room, ICU, etc. It can satisfy the requirement of parts of body such as head, limbs, chest, spine, lunbar, stomach.
Feature
· Equipped with the advanced pulse fluoroscopy technology, providing sharp image with low dose.
· Intelligent Image Processing function of software offering high-quality image.
· Flexible diagnostic table makes movement to meet all kinds of exposure needs.
Technical specification
Item | Content | Technical parameter |
Power Supply | Voltage | 380V±38V |
frequency | 50Hz±1Hz | |
capacity | ≥105kVA | |
internal resistance | ≤0.17Ω | |
High voltage generator | Maximum output power | 65.5kW |
Main inverter frequency | 500khz, tolerance ± 20% | |
Radiography tube voltage | 40kV~150kV | |
Radiography tube current | 10mA~800mA regulation in steps | |
Radiography time | 1ms~ 10000ms regulation in steps | |
Radiography mAs | 0.1~1000 mAs | |
Fluoroscopy voltage | 40kV~ 125kV Continuously adjustable | |
Fluoroscopy current | 0.5mA~ 10mA (Continuously fluoroscopy) | |
5mA~ 20mA (pulse fluoroscopy) | ||
Collimator | Equivalent total filtration | ≥1mmAL |
X ray tube | Nominal anode input power | Big focus 75kW small focus 27kW |
Anode heat capacity | 210KJ(300kHU) | |
Component heat capacity | 900kJ(1250kHU) | |
Rotating anode speed | 9700rpm(180 Hz) | |
Tube focus | Big focus 1.2mm / Big focus 0.6mm | |
Target angle | 12° | |
Diagnostic | Table rotating range | +90 ° ~ 0 ° ~ -25 ° |
Longitudinal movement of point device | 1000mm±20mm | |
Lifting range of bed surface | Not less than 300mm; tolerance ±10mm | |
The load-bearing capacity of the bed: | 200kg | |
SID | 1000mm~1800mm;Tolerance ± 20 mm | |
Rotating foot pedal(optional) | 360°Infinite rotation. | |
Filter grid | 498.5x449mm 230L/INCH 10:1,focal length:100cm | |
498.5x449mm 103L/INCH 10:1,focal length:180cm | ||
Dynamic flat panel detector | Effective area | 434mm(H)×434mm(V) |
Prime matrix | 3072(H)×3072(V) | |
Prime particle spacing | 139μm | |
Pulse fluoroscopy | 12fps / 1408 x 1408 | |
16fps / 1024 x 1024 | ||
22fps / 768x768 | ||
Continuous fluoroscopy | 13fps / 1408 x 1408 | |
20fps / 1024 x 1024 | ||
30fps / 768x768 | ||
Sequence radiography | 3fps/3072 x 3072 | |
6fps/1536 x 1536 | ||
Point piece | 3072 x 3072 | |
1536 x 1536 | ||
Spatial resolution | ≥3.7lp/mm | |
A / D Transformation | 16bit | |
Energy range | 40 ~ 150 kVp | |
Image output and control | Gigabit lan |
Configuration
Item | Model | Quantity | Remark |
Console | KZT70A | 1 | PLD |
High voltage generator | FSQ65RF | 1 | PLD |
X ray tube | E7252X | 1 | Canon |
Collimator | XSQ20 | 1 | PLD |
Diagnostic table | ZDC20F | 1 | PLD |
Grid | 1.0/1.8m | 2 | JPI |
Dynamic flat panel detector | DRF-1717A | 1 | PLD |
Image acquisition workstation | DRA80 | 1 | PLD |
Image processing software(Optional) | DRA50 | 1 | PLD |
Accessory | PLD6000 | 1 | PLD |