Category
Related Products
|
Order Code |
Product Name |
|
H-06-06-M01 |
21L Ethylene Oxide Sterilizer |
Application
Beauty clinics, medical and health departments, etc.
Feature & Technical specification
1. CE conformity. Product form: manual door table
2. Heating method: electric heating
3. Power: 3.3kVA
4. Power supply: AC220V 50Hz
5. Dimensions (L×W×H): 730×510×410mm
6. Liner size (diameter x depth): 246 x 450mm
7. Effective volume: 21L
8. Weight: 45kg
9. Display: 3.5 inch LCD screen
10. Sterilization chamber material: 304 stainless steel
11. Outer box material: ABS plastic
12. Temperature during sterilization: 50℃±3℃
13. Working pressure: -60kPa
14. The highest pressure resistance value: -80kPa
15. Humidity during sterilization: 40%-85%
16. Select gas pure ethylene oxide gas
17. Sterilization time: 0-999 hours adjustable
18. Pump the vacuum to -60kPa within 15 minutes
19. Water storage capacity distilled water tank 1.5L, decomposition water tank <1.5L
20. One-time sterilization water consumption: The water consumption of distilled water is less than 30mL, and the water consumption of decomposed water is less than 3L (directly related to the size of water pressure)
21. Automatic ventilation for air replacement, 5 times of ventilation, every 15 minutes
22. The sterilization record system can store 500 times of sterilization records
23. Display status Display running status, temperature, humidity, pressure, sterilization time, residual gas treatment time, times, steam generator temperature
24. The printer adopts a micro-printer, which prints out the data every minute in the whole process of sterilization, which can be stored permanently
25. The USB interface upgrades the system program and reads the historical data during the sterilization process
26. Humidity sensor The built-in humidity sensor automatically detects the humidity in the sterilization room
27. The built-in pressure sensor of the pressure transmitter automatically detects the pressure in the sterilization chamber
28. Temperature sensor The built-in temperature sensor automatically detects the temperature in the sterilization room
29. The vacuum system adopts oil-free vacuum pump
30. Sealed door 304 stainless steel aluminum, thickness ≥2mm, pressure resistance 200kPa
31. Pulsed steam humidification under negative pressure of humidification system
32. The filtration rate of the air filter device filter to the particle diameter>0.3μm, not less than 99.5%
33. Determination of the leak rate in the sterilization chamber The temperature of the sterilization chamber remains unchanged at no load, the test pressure is -70kPa, and the measurement time is 15min
34. The average leakage rate during the measurement time is ≤0.13kPa/min
35. Automatic dosing sterilization chamber built-in piercing technology
36. The heating system sterilization chamber adopts explosion-proof electric heating device
37. A variety of protection functions are provided with overvoltage and overtemperature protection functions, which are more secure and reliable
38. The alarm system includes high and low temperature alarm system, low pressure alarm system, steam high temperature alarm system, leak rate detection alarm system, sealed door detection alarm system, dosing detection alarm system
39. If the power is cut off during the sterilization process of the power-off memory function, the screen will prompt "Yes" or "No" to continue the last operation after the power is turned on again.
40. At this point, you can select "Yes" to continue the last run. You can also select No to cancel the run. If there is no operation for ten minutes, the system will select "Yes" by default and continue to operate in the working state when the power is cut off.
Contact Information
E-mail:
Tel:
Address : Room 2512, Unit 1, Huaqiao Square, No.1, Daqiao North Road, Jiangbei New District, Nanjing, China
Veterinary Equipment