Category
Related Products
|
Order Code |
Product Name |
|
H-04-07-M02 |
65KW rail flat bed dynamic DR |
Application
This high frequency digital x-ray equipment can meet different parts radiography, such as head, chest, abdomen, waist, lumber, thoracic, pelvis, limbs etc.
Feature
· Dynamic Digital Radiology--An enhanced X-ray technology that provides a series of individual digital images acquired at high speed and low dose.
· It Enables clinicians to observe the dynamic motion of anatomical structures over time, enhancing diagnostic capabilities.
· Basic functions:Large format (17*17inch) and high-definition radiography, fluoroscopy, real-time video storage and playback, visual contrast, millisecond spot film,
· It can be fixed digital x ray machine and we can use it at bus and truck.
Technical specification
Item | Content | Technical Parameters |
Power | Voltage | 380V±10% |
Frequency | 50Hz±1Hz | |
Capacity | ≥105kVA | |
Internal Resistance | ≤0.17Ω | |
High Frequency High Voltage X-Ray Generator | Power | 65.5KW |
Inverter Frequency | 500KHz±20% | |
Radiology Tube voltage | 40kV—150kV ,Steps 1kV | |
Tube current | 10mA—800mA | |
Exposure time | 1ms—10000ms | |
mAs | 0.1-800mAs | |
Fluoroscopy tube voltage | 40kV—125kV | |
Fluoroscopy tube current | 0.5mA-20mA(continues fluoroscopy) | |
5mA-40mA(pulse fluoroscopy) | ||
X-ray source assembly(TOSHIBA E7252X) | Input power | Big focus 75kW Small focus 27kW |
Anode thermal capacity | 210KJ | |
Anode maximum heat dissipation | 475W(667KHU/min) | |
Rotary anode speed | 9700rpm | |
Tube Focus:big/small | 1.2mm /0.6mm | |
DynamicWiFiFlat Panel Detector(DRF-1717V) | Active area | 427(H)×427(V) |
Pixel matrix: | 3072(H)×3072(V) | |
Pixel pitch: | 139 μm | |
Limiting resolution | 3.7lp/mm type | |
A / D transition: | 16bit | |
Energy range | 40 - 150 kVp | |
Maximum entrance dose (low gain) | 4 mR / frame | |
Power Input: | DC 24V 2A | |
Collimator (XSQ40) | View light: | Light Halogen, AC24V/100W |
Visible light exposure brightness Average illumination brightness: >100Lux | ||
Illuminator turn-on time limit up to 5~45S | ||
Bucky Stand(XPJ20C) | Up and down movement | Not less than 1500mm |
Table(SYC20D) | Lowest height | 550mm |
Table bearing | 200kg | |
Basic configuration
Configuration | Model No | Quantity | Remarks |
Control Console | KZT70D | 1 unit | PLD |
High voltage generator | FSQ65MRF | 1 set | PLD |
X-ray tube assembly | E7252X | 1 unit | Canon |
Collimator | XSQ40 | 1 unit | PLD |
Radiography Table | SYC20D | 1unit | PLD |
Bucky Stand | XPJ20C | 1 set | PLD |
Detector | DRF-1717V | 1 set | PLD |
Image acquisition workstation | DRA80 | 1 set | PLD |
Machine accessories | PLD7900I | 1 set | PLD |
AEC | SSMC601 | 1 set | PLD |
DAP | / | 1 set | PLD |
Contact Information
E-mail:
Tel:
Address : Room 2512, Unit 1, Huaqiao Square, No.1, Daqiao North Road, Jiangbei New District, Nanjing, China