Order Code |
Product Name |
|
H-05-13-M01 |
Ultrasound Transcranial Doppler Flow Analyzer |
Application
Ultrasound Transcranial Doppler Flow Analyzer (TDC) is an operation technique that uses ultrasound to detect intracranial blood flow. It is safe and non-invasive, and can be used for the diagnosis and research of intracranial and extracranial blood vessels. The detection of blood flow in superficial blood vessels can quantitatively evaluate the blood supply status of cerebral blood vessels and superficial blood vessels, and can provide a basis for diagnosing the nature, degree and scope of various cerebrovascular diseases. Mainly used in neurology, neurosurgery, intensive care unit, functional examination department, physical examination department, etc. in hospitals at all levels
Feature
· The Acoustic Transcranial Doppler Flow Analyzer is a portable, modular TCD instrument. It is a single-channel, single-depth TCD instrument with automatic envelope real-time calculation, movie playback, emboli tracking, reference value display, automatic report generation and many other practical functions.
· Equipped with 2MHz and 4MHz ultrasound probes, which can be used for intracranial blood vessel detection and extracranial blood vessel detection
· Parameter database: In-memory hospital clinical data on vascular parameters. The measured value can be compared with the reference value in real time, and abnormal data can be alarmed. The built-in standard reference blood flow spectrogram is convenient for the operator to switch at any time for comparative analysis.
· Emboli (HITS) detection technology: When an embolus (HITS) occurs, the signal shows jump waveforms and can be played back and identified, which is convenient for doctors to observe and analyze.
· High-sensitivity ultrasonic probe: The high-sensitivity ultrasonic probe using composite materials has better detection sensitivity and stronger signal-to-noise ratio than ordinary ultrasonic probes. The ultrasonic probe interface uses a metal push-pull self-locking connector, which has a more reliable connection, a more refined appearance and better anti-interference ability.
· Flexible report editing: There are multiple built-in report formats, which provide great convenience for doctors to write, edit and recall spectrum and data. There is also a parameter comparison display mode, and the diagnosis results are clear at a glance.
· Other technologies: dynamic and static envelopes, real-time display of spectrum, calculation of blood flow parameters; access to any medical record at any time, storage of blood vessel blood flow spectrum for movie playback
Technical specification
Number of channels | single channel |
Number of depths | single depth |
Number of probes | 2 |
FFT sample rate | 156/312/624 |
Ruler | 156/312/624 |
Sampling volume | 1-20mm |
Depth adjustment | 1-200mm |
Software gain range | 1-48dB or 0-7 level adjustable |
Transmit power | 0-800% or 0-100% adjustable |