Category
Related Products
|
Order Code |
Product Name |
|
H-09-03-M01 |
Dental CBCT(Without Cephalic) |
Feature
· It adopts high-end flat panel detector with high resolution, small distortion and uniform brightness.
· In pulse exposure mode, the X-ray source is activated only when needed. In the 18 s rotation process, the radiation only lasts for 4-8s, which effectively reduces the inspection dose and reaches the international advanced level.
· This series of proprietary three-dimensional reconstruction algorithm, the original two-dimensional sequence projection into three-dimensional volume image, can provide high-resolution sectional image at any angle, any position.
· High-definition panoramic images can be provided by extracting oral panoramic images from 3D volume images.
· Images can be used to generate reports, print or save as report files.
Technical specification
1. Technical indicators
1, electrical performance
1.1 Anode voltage: 60-92 kV
1.2 anode current: 1-15 mA
1.3 Maximum output power: 1.38kw
1.4 Main inverter frequency: 100kHz
1.5 parameter adjustment range: 60 ~ 92KV 1 ~ 15mA
1.6 Information display: KV, MA, lifting position information, human characteristics, laser
2. X-ray tube
2.1 ray tube Model: D-054SB (Canon)
2.2 Focus: 0.5mm
2.3 Heat capacity: 35kJ (50kHU)
2.4 photography mode: cone beam CT
3. Image system Thales flat panel detector 650HD-E
3.1 image receiving size: 12cmX15cm flat panel detector
3.2 pixel size: 150μm
3.3 A / D conversion depth: 14bit
3.4 Acquisition mode: pulse mode
3.5 Detector Type: CMOS
3.6 Pixel matrix: 960 * 786
3.7 Limit resolution up to: two-dimensional ≥ 1.5 lp / mm
3.8 Image size: φ120* 100
4. Structural Performance
4.1 Column lift stroke: 1000mm±50mm
4.2 Lifting noise:≤65dB (with buzzer sound)
4.3 Collision protection: Yes
4.4 Weight: 200kg
4.5 Dimensions: 975mm (width) X 1250mm (length) X 1970mm (height)
4.6 Power requirements: 220V / 50HZ /60HZ/ 2 kVA
4.7 Space requirements: the required area of 5 square meters, unilateral 2 meters
4.8 The camera room should have a protective thickness of 2 mm lead.
4.9 Electrical control device size: width 400mm, depth 180mm, height 300mm
Standard configuration
1、Main Frame 1 set
2、High Frequency High Voltage X-ray Generator 1 set
3、24 inch color ordinary LCD monitor 1 set
4、12cmX15cm flat panel detector 1 set
5、Digital Acquisition Processing Workstation 1 set
6、Electrically adjustable collimator 1 set
7、Graphical LCD touch screen 1 unit
8、Wall-mounted control box 1 unit
9、Electrical control cabinet 1 unit
10、Printer (optional) 1 set
Contact Information
E-mail:
Tel:
Address : Room 2512, Unit 1, Huaqiao Square, No.1, Daqiao North Road, Jiangbei New District, Nanjing, China
Veterinary Equipment
Medical Equipment